What this code requires
CMC 304.1 is the California Mechanical Code section that requires every appliance to be located so it can be accessed for repair or replacement, with working space of at least 30 inches in depth, width, and height unless otherwise specified. Attic and under-floor installs follow CMC 304.4. Clearances to combustibles come from the appliance listing and installation instructions under CMC 303.10, and the plan-checker is verifying that your drawings show both. Tight utility closets, under-stair installations, and attic furnace platforms are the most common spots where this gets flagged.
How to fix it
Pull the appliance nameplate listing and installation manual
Before you revise the drawings, get the make and model of every fuel-burning appliance on the plan and download the manufacturer's installation instructions. The listed clearances on the nameplate are what CMC 303.10 actually requires (not a generic table), and CMC 904.3.1 says the same for listed furnaces and boilers. For most residential gas furnaces the sides are 0-1 inch, the rear 0-1 inch, the top 1-6 inches, and the front service area 30 inches — but those numbers vary by model, and the plan-checker will flag any discrepancy between what's on the drawings and what the nameplate says.
Add a clearance schedule to the mechanical plan sheet
Create a clearance schedule (a simple table works) on the M-series or floor plan sheet that lists each appliance by tag, model number, and its required clearances from the nameplate: top, sides, rear, front (service clearance). Reference it in a note: 'All appliances installed per manufacturer's listed clearances per CMC 303.10 and 304.1.' This gives the plan-checker a single place to verify compliance without hunting through the drawings.
Dimension the clearances on the installation detail
For any appliance in a closet, alcove, or tight mechanical room, draw a plan-view detail at 1/4"=1' or larger showing the appliance outline and the required clearance envelope as a dashed zone. Dimension each side explicitly. The 30-inch front service clearance is the one that most commonly fails — show that the door swing (or fully open door) does not intrude into it. If it does, note the door type change (swing-out, bi-fold, or sliding) right on the detail.
Verify and show attic or crawl-space access dimensions
If the appliance is in an attic or crawl space, confirm the access meets CMC 304.4: an opening and passageway at least 22" x 30" and larger than the largest appliance component, solid flooring at least 24" wide, a passageway no longer than 20 feet where under 6 feet high, and a level 30" x 30" platform at the service side. Show the access hatch on the plan with dimensions and a note indicating its location. The path from the hatch to the appliance must be passable — a furnace at the far end of a narrow attic with no walking surface is a service access failure even if the clearance envelope around the unit itself is correct.
Address combustion air if in a confined space
Appliances in closets or small mechanical rooms that fall below the volume threshold for unconfined space need combustion air openings per CMC 701. If your enclosure is under roughly 50 cubic feet per 1,000 BTU of total appliance input, show the combustion air openings (size, location, and whether they're high/low) on the plan. Plan-checkers often cite CMC 304.1 and CMC 701 together on confined-space installations, so fixing access and clearance without addressing combustion air just generates a second correction.
Note the gas connection type on the detail
Show whether the gas connection is rigid or flex, and confirm the flex connector length doesn't exceed the limit for the appliance type. A flex connector crowded against a wall inside the listed rear clearance is a double failure. Calling out the connector type and length on the detail heads off a separate gas-connection comment that often appears alongside the access and clearance correction.
Resubmit with a response letter keyed to each comment
When you resubmit, include a written response to each plan-check comment. For the access and clearance comment, cite the sheet and detail number where you added the clearance schedule and dimension detail. Plan-checkers have dozens of projects open. A one-page response letter that says "CMC 304.1: see M-1 clearance schedule and Detail 3/M-2 for dimensioned clearance envelope" gets you through the second round faster than a clean redline with no narrative.
Take the CMC 304.1 fix steps with you
All 7 steps in one email, so you have them on site instead of on this page.
Why you got flagged
Plan-checkers flag CMC 304.1 when the drawings don't show that the space around an appliance is sufficient for both the required clearance to combustibles and the service technician who'll work on it over the life of the equipment.
The most common trigger is a furnace or water heater crammed into a closet with no clearance dimensions called out on the plan. The code requires the clearances from the appliance listing (CMC 303.10) plus the 30-inch working space (CMC 304.1), and if those numbers aren't on the drawings, the plan-checker can't confirm compliance.
Attic and crawl-space installations get flagged for inadequate access. Even if the clearances are technically fine once you're inside, the route to the appliance has to meet CMC 304.4: an access opening at least 22 by 30 inches, a solid floor at least 24 inches wide, and a level 30-by-30-inch platform at the service side. A plan that shows the furnace location but skips the access hatch dimensions will get kicked back.
Closet installations also fail when the door opens into the required service clearance. If a furnace is 4 inches from the door and the code requires 30 inches of working clearance in front, that door needs to swing out or be a bi-fold that doesn't eat into the front clearance. Plans that show a standard interior door without noting the clearance arithmetic are a common source of corrections.
The official code
2025 California Mechanical Code (Title 24, Part 4) Section 303.10 Clearance to Combustible Materials and Section 304.0 Accessibility for Service, via California Building Standards Commission
Read the source →