What this code requires
CRC R318.2 requires every dwelling unit to have at least one egress door measuring a minimum 32 inches of clear width and 78 inches in height. The door must be side-hinged and operable from the inside without a key, special tool, or special knowledge. Most single-family and ADU permits hit this correction when door dimensions are missing from the plans or the required egress door isn't labeled on the floor plan.
How to fix it
Identify and label the egress door on the floor plan
Pick the door that will serve as the required egress door for the unit and add a clear label on the floor plan sheet, such as 'REQUIRED EGRESS DOOR PER CRC R318.2.' This tells the plan-checker exactly which door you're counting. Every unit needs at least one. For ADUs, the ADU itself needs its own compliant egress door separate from the main house. The egress door must exit directly to the exterior, so a door into an attached garage doesn't count. Pick a door that leads straight outside.
Call out 32-inch minimum clear width in the door schedule
In your door schedule, list the egress door with a note specifying minimum 32 inches clear width. A 3-0 (36-inch) door is the safe call and gives you plenty of clear margin. A 2-10 (34-inch) door in a standard frame typically yields just over 32 inches clear, but it's tight and depends on frame tolerances. A 2-8 (32-inch) door will not pass because the frame and stop eat into the clear dimension. Write '32" CLEAR MIN' explicitly in the door schedule so there's no ambiguity. If the plan checker has to calculate it, you might not like the answer.
Note the door height as 78 inches minimum
The egress door must be at least 78 inches tall. Standard 6-8 (80-inch) doors meet this easily. If your design uses a non-standard door height, for example in a remodel where the existing rough opening is short, confirm the clear height in the door schedule. Note the height on both the floor plan door symbol and the door schedule. If there's any question about tight rough openings, add a detail showing the rough opening dimensions and how they translate to clear height after installation.
Confirm the door is side-hinged, not sliding or folding
Sliding doors, bi-fold doors, roll-up doors, and pocket doors do not satisfy the egress door requirement. The door must be side-hinged, meaning it swings on a vertical hinge axis. If your design shows a sliding glass door as the primary exit, you need a separate side-hinged door elsewhere in the unit to serve as the egress door. Note 'SIDE-HINGED' in the door schedule next to the egress door entry. It seems obvious, but plan-checkers want to see it in writing.
Specify single-cylinder hardware — no double-cylinder deadbolts on the egress door
The hardware schedule must not specify a double-cylinder deadbolt on the egress door. Double-cylinder locks require a key from both sides. Single-cylinder deadbolts are fine: they lock with a key from outside, but release with a thumb-turn from inside. Add a note to the egress door entry in your hardware schedule: 'SINGLE-CYLINDER DEADBOLT ONLY. NO KEY REQUIRED FROM INTERIOR PER CRC R318.2.' This is a fast correction to catch in review before submittal. It's a slow correction to fix after a rejection letter.
Cross-reference the egress door on exterior elevations
Some plan-checkers want to see the egress door called out on the exterior elevation sheet as well, not just the floor plan. Add a leader note on the elevation pointing to the door: 'EGRESS DOOR, 32" CLEAR MIN WIDTH, 78" MIN HEIGHT, PER CRC R318.2.' This cross-reference between sheets reduces the chance of a second round of corrections. It takes two minutes to add and can save sixty days waiting on a resubmittal.
Check ADUs and new units for a dedicated egress door
If your permit includes an ADU or a room addition that creates a new dwelling unit, that unit needs its own R318.2-compliant egress door. A shared door through the main house does not count, even if the main house has a compliant egress door. The egress door must exit directly to the exterior, giving occupants a path out without passing through another unit. This is one of the most common R318.2 corrections on ADU permits. Reviewers check this specifically when they see an attached ADU sharing a wall with the main house.
Take the CRC R318.2 fix steps with you
All 7 steps in one email, so you have them on site instead of on this page.
Why you got flagged
Plan-checkers flag R318.2 most often because door dimensions simply aren't on the submitted plans. A floor plan that shows a door swing without a width callout gives the reviewer no way to verify compliance. Even if the door you're planning to use meets the 32-inch clear-width requirement, the plan check fails because the inspector can't confirm it from the drawing.
The second common trigger is confusion between door size and clear width. A 32-inch-wide door in a standard frame gives you about 29-1/2 to 30 inches of clear opening. That's under the minimum. To get 32 inches of clear, you typically need a 34-inch door unit. If the plans call out a 32-inch door without specifying 'clear,' the plan-checker will flag it.
Another scenario: the door is shown and dimensioned correctly, but it's not labeled as the required egress door. The plan-checker needs to confirm there's at least one compliant egress door per unit. If your floor plan has three exterior doors and none are tagged as the egress door, the reviewer may flag the whole unit even if one of them meets the spec.
Finally, double-cylinder deadbolts catch contractors off guard. A double-cylinder lock requires a key from both sides, which violates the 'operable from inside without a key' requirement in R318.2. If the hardware schedule calls out a double-cylinder deadbolt on the egress door, expect a correction on the next round.