What this code requires
CEC 210.70 is the California Electrical Code section that requires wall-switched lighting outlets in every habitable room, bathroom, hallway, and stairway, and at each exterior door. The requirement applies to new residential construction and additions. Plan-checkers flag it when the lighting plan omits switched outlets from required locations or shows pull-chain or plug-in fixtures in their place.
How to fix it
Confirm which rooms and spaces require a switched outlet
Pull the floor plan and mark every habitable room (bedroom, living room, dining room, den, home office, sunroom), the kitchen, every bathroom, every hallway, every stairway, attached and detached garages with power, and every outdoor entrance. CEC 210.70 requires a wall-switched lighting outlet in each of these locations. If your project is a remodel or addition, the requirement applies to new and altered spaces — verify the scope of work matches what you marked.
Add wall-switch symbols at each required location
On the electrical plan, place a wall-switch symbol (S) at each required space. The switch must control at least one lighting outlet in that room or at that exterior door. If the room has multiple lighting outlets (e.g., a bedroom with both a ceiling fixture and a closet light), only one needs to be wall-switched — but the plan must show the connection clearly. Use a dashed line on the plan to indicate which switch controls which fixture, so the plan-checker doesn't have to guess.
Verify fixture type qualifies as a lighting outlet
A switched lighting outlet means a box or prewire location intended specifically for a light fixture — not a general-purpose receptacle. A GFCI outlet above the vanity does not satisfy CEC 210.70 even if a plug-in light is used. A junction box with a pull chain qualifies if wall-switched from a separate switch, but that configuration is uncommon in new construction. Ceiling fan boxes qualify if they are wired with a separate switched leg for the light kit. Confirm each symbol on the plan represents a real switched fixture location.
Show exterior door fixtures on both floor plan and elevation
Exterior lighting outlets need to appear on the floor plan (switch location inside) and on the exterior elevation (fixture location outside). A common mismatch: the fixture shows on the elevation but the switch is not on the floor plan. Add an exterior lighting note on the floor plan that cross-references the elevation sheet and label the switch-to-fixture relationship. Both sheets must agree, or the plan-checker will flag it as unresolved.
Check stairways for switch placement at each floor and landing
CEC 210.70 requires a wall-switched lighting outlet in each hallway and stairway. Where an interior stairway has six or more risers, a switch is required at each floor level and at each landing level that includes an entryway, not just one end. A stairway between two floors needs switches at the top and bottom. Show the three-way or four-way switch wiring on the plan. If the plan shows a single switch at one end of a qualifying stairway, the plan-checker will flag the missing switches.
Update the electrical schedule or fixture legend
If your plan set includes an electrical fixture schedule, make sure every newly added switched outlet appears in it with a fixture type, wattage or lumens rating, and switch designation. Missing entries in the schedule create a second path to a correction — even if the floor plan looks correct, a plan-checker using the schedule as a checklist will note the gap. Keep the schedule and floor plan in sync.
Include a code compliance note on the electrical sheet
Add a general note on the electrical plan sheet: ‘All habitable rooms, bathrooms, hallways, stairways, and exterior doors provided with wall-switched lighting outlets per CEC 210.70.’ This note does two things: it signals to the plan-checker that you are aware of the requirement, and it anchors the correction if they still flag it — they have to respond to the note, not just circle a missing symbol. A one-line note is faster to write than a resubmittal.
Take the CEC 210.70 fix steps with you
All 7 steps in one email, so you have them on site instead of on this page.
Why you got flagged
Most corrections citing CEC 210.70 come down to one of a few situations: the lighting plan simply doesn't show a switched outlet where the code requires one.
The most common scenario is a habitable room listed on the floor plan with no lighting outlet shown at all. Living rooms, bedrooms, and home offices all qualify as habitable space, so every one of them needs a wall switch controlling at least one lighting outlet. If the drawing shows a ceiling fan with no light, a canned light on a dimmer not wired to a wall switch, or just an empty room, the plan-checker will flag it.
Bathrooms get flagged separately and often. The code requires a wall switch at the bathroom entrance controlling at least one lighting outlet. If the electrical plan shows only a plug-in fixture over the vanity or shows the fixture controlled from the GFCI outlet rather than a separate switch, that's a correction.
Hallways and stairways are a frequent miss on remodels. If the project adds square footage or changes a floor plan, the plan-checker will look at every hallway and stair in the affected area. A hall without a switched lighting outlet at each point of entry is a flag, even if natural light makes the space feel usable.
Exterior doors are another common omission. Each exterior door needs a switched lighting outlet nearby — interior switch, exterior fixture is the typical configuration. Contractors often show the fixture on the exterior elevation but forget to carry the switch symbol back to the floor plan, so the plan-checker sees an inconsistency and flags it.
The official code
California Electrical Code (Title 24 Part 3), Section 210.70 — Lighting Outlets Required